Indoor unit |
CC32-12CA(I) |
Outdoor unit |
CC32-12CA(O) |
Power supply |
115V~/60Hz/1P |
Cooling |
Rated cooling capacity(95F/35C) |
Btu/h |
11500 |
Rated current |
A |
10 |
Rated input |
W |
1150 |
Max Current |
A |
13.0 |
Current Range |
A |
2.0~13 |
EER2 (95F/35C) for cooling |
Btu/W.h |
10.00 |
SEER2 for cooling |
Btu/W.h |
17 |
Moisture removal |
Pint/h |
3.17 |
Indoor air circulation-Turbo/Hi/Mid/Lo/Mute |
CFM |
250/235/218/200/182 |
Indoor noise level at cooling-Turbo/High/Med./Low/Mute |
dB(A) |
43.7/40.3/35.7/33.2/28.2 |
Indoor unit |
Net dimensions |
Inch |
30.59x9.84x7.91 |
Net weight |
Lbs. |
16.5 |
Packing dimensions |
Inch |
33.07x12.40x10.23 |
Gross weight |
Lbs. |
20.9 |
Outdoor noise level |
dB(A) |
54.4 |
Outdoor unit |
Net dimensions |
Inch |
30.98x11.41x19.60 |
Net weight |
Lbs. |
46.3 |
Packing dimensions |
Inch |
32.99x13.30x21.25 |
Gross weight |
Lbs. |
52.9 |
Refrigerant |
oz |
R32/17.60 |
Additional refrigerant charge |
oz/ft |
0.11 |
Connecting Pipe |
Gas |
Inch |
3/8'' |
Liquid |
Inch |
1/4'' |
Connecting Wiring |
Size x Core number |
|
4×16AWG |
Suitable area |
sq.ft |
Up to 550 |
Indoor Ambient temperature(Cooling) |
℉ |
>=62 |
Outdoor Ambient temperature(Cooling) |
℉ |
53.6~122 |
Service Code |
Indoor |
21B |
Outdoor |
21C |