Test Spec Sheet

Indoor unit CC32-12CA(I)
Outdoor unit CC32-12CA(O)
Power supply 115V~/60Hz/1P
Cooling Rated cooling capacity(95F/35C) Btu/h 11500
Rated current A 10
Rated input W 1150
Max Current A 13.0
Current Range A 2.0~13
EER2 (95F/35C) for cooling Btu/W.h 10.00
SEER2 for cooling Btu/W.h 17
Moisture removal Pint/h 3.17
Indoor air circulation-Turbo/Hi/Mid/Lo/Mute CFM 250/235/218/200/182
Indoor noise level at cooling-Turbo/High/Med./Low/Mute dB(A) 43.7/40.3/35.7/33.2/28.2
Indoor unit Net dimensions Inch 30.59x9.84x7.91
Net weight Lbs. 16.5
Packing dimensions Inch 33.07x12.40x10.23
Gross weight Lbs. 20.9
Outdoor noise level dB(A) 54.4
Outdoor unit Net dimensions Inch 30.98x11.41x19.60
Net weight Lbs. 46.3
Packing dimensions Inch 32.99x13.30x21.25
Gross weight Lbs. 52.9
Refrigerant oz R32/17.60
Additional refrigerant charge oz/ft 0.11
Connecting Pipe Gas Inch 3/8''
Liquid Inch 1/4''
Connecting Wiring Size x Core number   4×16AWG
Suitable area sq.ft Up to 550
Indoor Ambient temperature(Cooling) >=62
Outdoor Ambient temperature(Cooling) 53.6~122
Service Code Indoor 21B
Outdoor 21C